Series 24 CSR闭锁继电器Series 24 CSR
详细信息
| 品牌:Electroswitch | | 型号:Series 24 CSR | | 应用范围:Series 24 | |
| 额定电流:10 A | | 额定电压:220 V | | 触点负载:50 | |
| 触点切换电流:50A | | 触点形式:自动 | | 防护特征:Series 24 | |
Series 24 CSR闭锁继电器Series 24 CSR产品介绍:
Electroswitch Control Switch Relays (CSR) combine the function of a control switch with a
remote controlled solenoid allowing one device to do both the manual and supervisory control
function in the control of power circuit breakers. They eliminate the need to redesign substations
for redundant separate relays when manual substations convert to supervisory control.
CSRs provide manual or electric control switch operation by supervisory control. The CSR
looks, acts, and feels identical to a control switch.
Note: The Series 24 CSR Class 1E utility products comply with the following Nuclear
Standards: ANSI/IEEE C37.90, ANSI/IEEE C37.90.01, ANSI/IEEE C37.98, ANSI/IEEE
C37.105, ANSI/IEEE 323, ANSI/IEEE 344, ANSI/ASME NQA -1.
Series 24 CSR闭锁继电器Series 24 CSR产品选型:
Series 24 CSR 38CA-38CA;Series 24 CSR 38CB-38CB;Series 24 CSR 38CC-38CC;
Series 24 CSR 38DA-38DA;Series 24 CSR 38DB-38DB;Series 24 CSR 38DC-38DC;
Series 24 CSR 40CA-40CA;Series 24 CSR 40CB-40CB;Series 24 CSR 40CC-40CC;
Series 24 CSR 40DA-40DA;Series 24 CSR 40DB-40DB;Series 24 CSR 40DC-40DC;
Series 24 CSR 41CA-41CA;Series 24 CSR 41CB-41CB;Series 24 CSR 41CC-41CC;
Series 24 CSR 41DA-41DA;Series 24 CSR 41DB-41DB;Series 24 CSR 41DC-41DC;
Series 24 CSR 42CA-40CA;Series 24 CSR 42CB-42CB;Series 24 CSR 42CC-42CC;
Series 24 CSR 42DA-40DA;Series 24 CSR 42DB-42DB;Series 24 CSR 42DC-42DC;
Series 24 CSR 43CA-41CA;Series 24 CSR 43CB-43CB;Series 24 CSR 43CC-43CC;
Series 24 CSR 43DA-41DA;Series 24 CSR 43DB-43DB;Series 24 CSR 43DC-43DC;
Series 24 CSR 44CA-44CA;Series 24 CSR 44CB-44CB;Series 24 CSR 44CC-44CC;
Series 24 CSR 44DA-44DA;Series 24 CSR 44DB-44DB;Series 24 CSR 44DC-44DC;
Series 24 CSR 45CA-45CA;Series 24 CSR 45CB-45CB;Series 24 CSR 45CC-45CC;
Series 24 CSR 45DA-45DA;Series 24 CSR 45DB-45DB;Series 24 CSR 45DC-45DC;
Series 24 CSR 46CA-46CA;Series 24 CSR 46CB-46CB;Series 24 CSR 46CC-46CC;
Series 24 CSR 46DA-46DA;Series 24 CSR 46DB-46DB;Series 24 CSR 46DC-46DC;
Series 24 CSR 50CA-50CA;Series 24 CSR 50CB-50CB;Series 24 CSR 50CC-50CC;
Series 24 CSR 50DA-50DA;Series 24 CSR 50DB-50DB;Series 24 CSR 50DC-50DC;
Series 24 CSR 52CA-45CA;Series 24 CSR 52CB-52CB;Series 24 CSR 52CC-52CC;
Series 24 CSR 52DA-45DA;Series 24 CSR 52DB-52DB;Series 24 CSR 52DC-52DC;
Series 24 CSR 57CA-45CA;Series 24 CSR 57CB-57CB;Series 24 CSR 57CC-57CC;
Series 24 CSR 57DA-45DA;Series 24 CSR 57DB-57DB;Series 24 CSR 57DC-57DC;
Series 24 CSR 58CA-45CA;Series 24 CSR 58CB-58CB;Series 24 CSR 58CC-58CC;
Series 24 CSR 58DA-45DA;Series 24 CSR 58DB-58DB;Series 24 CSR 58DC-58DC;
Series 24 CSR闭锁继电器Series 24 CSR性能描述:
Series 24 Control Switch Relays
HIGH QUALITY • Designed and manufactured to the highest standards
in the industry
• Qualified to UL, CSA, ANSI/IEEE 37.90 and 37.90 .1
VERSATILITY • Replaces a manual breaker switch, interposing relays, and
associated wiring
• Direct retrofit to existing manual breaker control switch
• Electric or manual operation
• Three circuits to satisfy different industry applications
• Multiple voltages: 48VDC, 125VDC, standard, others available
• All standard Series 24 circuit breaker control switch contacting
(see page 17) available
• Available with custom contacting (consult factory)
SAFETY • Target flag agreement (regardless of manual or electric trip)
• Available with SCADA disable for operator safety during service
• 1E Nuclear qualified
AVAILABILITY • Virtually all Universal Circuits in standard voltages of the Series
24 CSRs are available from stock for quick delivery. See pg.14
(Switch Section) for Series 24 Universal Circuits.
SERVICE • The Electroswitch team of Customer Service and Applications
Professionals stand behind every Electroswitch product.
Series 24 CSR闭锁继电器Series 24 CSR产品操作:
Basic Circuit Operation
The control of the CSR Control Switch Relay for electric operation requires no special wiring. It
only requires two contacts (S1 and S2) to command the CSR to either the TRIP or CLOSE
position. Low level contacts (rated 1 ampere) may be used since S1 and S2 do not control
the rotary drive solenoid directly.
The standard station control bus voltage is used on all three circuits. The device, when shown
in the following figures is in the vertical NORMAL position. The CSR coil form shown on the
figures represents the rotary solenoid that drives the CSR. Its operation is further described
later. LS1 is a linear solenoid within the device that changes the sense of direction of the CSR
from left (TRIP) to right (CLOSE). The contacts shown as CSR are contacts within the device.
Other components are shown by conventional designations.
Mechanical Target
When the CSR Switch handle is turned, a mechanical target contained in the nameplate is
turned as well (GREEN for TRIP, RED for CLOSE). The target remains latched when the handle
returns to normal position and always shows the last active position.